Lactate threshold models: why one athlete got four different answers
A lactate threshold is not a fact about an athlete. It is a fact about an athlete, a protocol and a definition. Change any one of the three and the number moves.
Blood lactate rises in two bends as exercise gets harder. The first bend, LT1, is where lactate first climbs above resting levels. The second, LT2, is where it starts to accumulate faster than the body clears it. Everything in between is the range most endurance training is built on. The physiology is settled. How a lab turns a handful of blood samples into those two numbers is not, and a 2009 review identified 25 different threshold concepts in the literature (Faude et al.).
The models in use
- Fixed 4 mmol/L (Mader, often called OBLA): the speed or power where lactate crosses 4 mmol/L. Simple and repeatable. It ignores that athletes differ: a well-trained endurance athlete with low lactate values crosses 4 mmol/L late, above the intensity they can actually sustain.
- Individual anaerobic threshold (Stegmann, Dickhuth and variants): the threshold is set relative to the athlete's own curve, for example a fixed rise above the lowest lactate-to-speed ratio. Designed to fix the problem with fixed values.
- Dmax: draw a line from the first to the last point of the curve and take the point on the curve furthest from it (Cheng et al., 1992). Sensitive to where the test starts and stops.
- Ventilatory thresholds (VT1, VT2): read from breathing gases with a mask, not from blood. They often land close to LT1 and LT2 but measure a different signal.
A 2020 review of the methods used to prescribe exercise intensity concluded that they are not interchangeable and that none of them is a gold standard for every athlete (Jamnick et al.).
The protocol moves the number too
Lactate lags behind the effort. With 1-minute steps, blood values trail the workload and the curve shifts to the right. With 3- to 5-minute steps, lactate has time to settle. Starting speed, step size, treadmill gradient and calibration all shift the curve, which is why test design matters as much as the threshold model (Bentley et al., 2007).
One athlete, four answers
The editor of this site, Thomas Prommer, did five lab tests between May 2024 and September 2026 in Singapore, Saigon and Erlangen. Four of them illustrate the point:
| When | Where | Sport | Model | Threshold |
|---|---|---|---|---|
| May 2024 | Singapore | Run | Fixed 4 mmol/L (Mader) | 13.2 km/h at HR 173 |
| Oct 2024 | Saigon | Run, indoor treadmill | None written. 5-minute steps from walking pace | 4 mmol/L just under 11 km/h when read off the sheet |
| Jan 2025 | Erlangen | Run | Gas analysis with lactate | LT1 11.2 km/h (HR 149), LT2 13.6 km/h (HR 166) |
| Sep 2026 | Erlangen | Bike | Individual anaerobic threshold with gas analysis | 249 W at HR 164, at 4.0 mmol/L |
The run thresholds range from just under 11 to 13.6 km/h over eight months. Fitness did not swing by close to 3 km/h. The model, the step length and the machine changed.
Same data, two models
The January 2025 Erlangen test makes the point cleanly because the raw step table is in the report: 8 km/h plus 1.5 km/h every 3 minutes, with lactate of 1.7 mmol/L at 12.5 km/h, 3.2 at 14.0 km/h and 5.4 at 15.5 km/h. The lab set LT2 at 13.6 km/h using gas analysis. Applying a fixed 4 mmol/L rule to the same numbers puts the threshold at about 14.5 km/h, by straight-line interpolation between the 14.0 and 15.5 km/h steps. Same blood, same day, almost 1 km/h apart.
For this athlete the fixed value overshoots, which is the pattern expected of someone with a low lactate response. Training threshold intervals at 14.5 km/h would put most of them above what can be sustained.
Run and bike are separate tests
The September 2026 test was on a bike, during a break from running after a femur fracture. The anaerobic threshold sat at 249 W and a heart rate of 164. Thresholds and heart rates differ between cycling and running, so a bike result cannot be converted into run zones. It is a separate baseline.
The shorter version
- A threshold is defined by a model. Ask which one the lab uses.
- Fixed 4 mmol/L is repeatable but tends to overshoot in well-trained endurance athletes.
- Compare results only within the same lab, protocol and sport.
- Step length of 3 minutes or more gives lactate time to settle.
The first-person story of all five tests, with the reports, is on prommer.net. How to book a test and turn it into zones is on hybridtraining.guide. The short definition is in the glossary under lactate threshold.
FAQ
- Why do two labs give different lactate thresholds for the same athlete?
- They use different definitions of the threshold (a fixed 4 mmol/L point, an individual threshold, Dmax or ventilatory thresholds), different step lengths and different machines. Each choice moves the number, often by 0.5 to 1 km/h or more for a runner.
- Is the 4 mmol/L lactate threshold accurate?
- It is reproducible but not individual. Athletes with a low lactate response reach 4 mmol/L well above their true maximal lactate steady state, and athletes with a high response reach it below. Individual models were developed to correct for that.
- What is the difference between LT2 and VT2?
- LT2 is read from blood lactate, VT2 from breathing gases (the respiratory compensation point). They often sit close together but are not the same measurement, so results from the two methods should not be mixed.